Cause:
- Sensor error I out of range (displayed on the main screen).
- No current in the circuit or offset measurement.
Action:
- Check if the issue occurs in both charge and discharge modes.
- Check the On/Off and C/D contactors.
- Check the control cables.
- Replace the contactors if necessary (tightening torque: 8.00 Nm).
- Check the consistency of the current measurement.
- Check the current sensor measurement cable.